APPLICATION: MEASURING THE TOTAL VOLUME OF COLD POTABLE WATER PASSING THROUGH THE METER. 
  
OPERATING CONDITION:  
THE MAX.ADMISSIBLE PRESSURE 1.6MPa 
RESISTING WATER TEMPERATURE OF 50℃ 
  
SPECIALITY: 
*SEMI-POSITIVE ROTARY PISTON TYPE 
* STRIGHT READING REGISTER  
*MAGNETIC TRANSMISSION AND WITH MAGNETIC SHIELD                 
* INSTALLATION IN ANY POSITION 
* ROBUST AND RUGGED CONSTRUCTION
  
  
Maximum permissible error: 
Between qt (included) and qs is ±2%; 
Between qmin and qt (excluded) is ±5%. 
NOTE: The technical data conform to ISO4064 standard, class C. 
 FLOW-ERROR CURVE 
 SPECIFICATION AND OVERALL DIMENSIONS
  
| 
 Description  | 
 Unit  | 
 Hydraulic data and dimensions  |  
| 
 Nominal size   | 
 mm  | 
 DN15  |  
| 
 Overload flow-rate (qs)  | 
 m3/h   | 
 3  |  
| 
 Permanent flow-rate (qp)  | 
 m3/h   | 
 1.5  |  
| 
 Transitional flow-rate (qt)  | 
 l/h   | 
 22.5  |  
| 
 Minimum flow-rate (qmin)  | 
 l/h   | 
 15  |  
| 
 Min. reading  | 
 1  | 
 0.05  |  
| 
 Max. reading  | 
 m3  | 
 99999.9999  |  
| 
 Nominal pressure  | 
 MPa  | 
 1.6  |  
| 
 ΔP at the qs  | 
 MPa  | 
 0.086  |  
| 
 I  | 
 mm  | 
 165  |  
| 
 L  | 
 mm  | 
 245  |  
| 
 G  | 
 inch  | 
 G3/4B  |  
| 
 H  | 
 mm  | 
 118  |  
| 
 Weight  | 
 With connections  | 
 kg  | 
 1.45  |  
| 
 Without connections  | 
 1.28  |   
OVERALL DIMENSIONS    PRESSURE LOSS CURVE
    |