APPLICATION:MEASURING THE TOTAL VOLUME OF COLD POTABLE WATER PASSING THROUGH THE METER,IT IS SUITABLE FOR DOMESITIC USE. 
SPECIAL FEATURE: 
* SIMPLE DESIGN  
* HERMETICALLY SEALED REGISTER 
* MINERAL TEMPERED GLASS 
* HIGH ACCURACY  
* NEGLIGIBLE HEAD LOSS AT WORKING FLOW-RATE  
* MAGNET DRIVE WITH ANTI-MAGNETIC SHIELD 
* HIGH-QUALITY MATERIAL WITH LONG LIFE OF SERVICE 
* REMOTE READING SYSTEM, RELIABLE IN DATA COLLECTING 
* WITH THE PULSE DEVICE, AND THE MEASURED WATER VOLUME OF PER PULSE MAY BE 1L/P, 1L/P OR 1L/P. 
WORKING CONDITION: 
* The max. admissible water pressure: 1.6MPa 
* Water temperature:  Cold water temperature up to 50℃ 
Hot water temperature up to 90℃(Available) 
Maximum permissible error: 
Between qt (included) and qs is ±2%; 
Between qmin and qt (excluded) is ±5%. 
NOTE: The technical data conform to ISO4064 standard, class B.
  
FLOW-ERROR CURVE
  
  
SPECIFICATION AND OVERALL DIMENSIONS
   
| 
 Description  | 
 Unit  | 
 Hydraulic data and dimensions  |  
| 
 Nominal size  | 
 mm  | 
 15   | 
 20  |  
| 
 inch  | 
 1/2  | 
 3/4  |  
| 
 Overload flow-rate (qs)   | 
 m3/h  | 
 3  | 
 5  |  
| 
 Permanent flow-rate (qp)   | 
 m3/h  | 
 1.5  | 
 2.5  |  
| 
 Transitional flow-rate (qt)   | 
 l/h  | 
 120  | 
 200  |  
| 
 Minimum flow-rate (qmin)   | 
 l/h  | 
 30  | 
 50  |  
| 
 Min. reading   | 
 l  | 
 0.05  | 
 0.05  |  
| 
 Max. reading   | 
 m3  | 
 99999.9999  | 
 99999.9999  |  
| 
 Max. working pressure   | 
 MPa  | 
 1.6  | 
 1.6  |  
| 
 ΔPmax at qs  | 
 MPa  | 
 ≤0.1  | 
 ≤0.1  |  
| 
 L  | 
 mm  | 
 165  | 
 190  |  
| 
 I  | 
 mm  | 
 245  | 
 294  |  
| 
 B  | 
 mm  | 
 86  | 
 86  |  
| 
 G  | 
 inch  | 
 G 3/4 B  | 
 G 1 B  |  
| 
 R  | 
 inch  | 
 R 1/2  | 
 R 3/4   |  
| 
 h  | 
 mm  | 
 126  | 
 126  |  
| 
 H  | 
 mm  | 
 200  | 
 200  |  
| 
 Weight   | 
 Without connections   | 
 Kg  | 
 1.02  | 
 1.18  |  
| 
 With connections   | 
 1.20  | 
 1.46  |    OVERALL DIMENSIONS                                                               PRESSURE LOSS CURVE
   |